Get Oct-2023 Download Latest & Valid Questions For Network Appliance NS0-593 exam [Q23-Q39]

Share

Get Oct-2023 Download Latest & Valid Questions For Network Appliance NS0-593 exam

Ensure Success With Updated Verified NS0-593 Exam Dumps


Earning the Network Appliance NS0-593 certification demonstrates that a candidate has the skills and knowledge required to support NetApp ONTAP technology. NetApp Certified Support Engineer ONTAP Specialist certification is recognized by IT professionals and organizations around the world and can help individuals advance in their careers. Certification holders are also able to demonstrate their expertise to potential employers and clients, which can lead to new opportunities and increased earning potential.

 

NEW QUESTION # 23
A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message
in the SP log.
Which FIFO message Is useful for Investigating this Issue?

  • A. before Reset BBSP:C=00 L=00 FIFO:
  • B. BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11
  • C. before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A
  • D. ONTAP Shutdown BBSP:C=00 L=2F FIFO:

Answer: B


NEW QUESTION # 24
You are trying to deploy a Connector in the AWScloud from NetApp Cloud Manager. The deployment fails
and shows the message 'Insufficient permissions to deploy Cloud Connector". You have verified the AWS
access key and the AWS secret key.
In this scenario, what Is the reason that the deployment failed?

  • A. The Connector can be deployed only inAWS GovCloud (US).
  • B. No AWS Marketplace subscription is associated with Cloud Manager.
  • C. The required Identity and Access Management (IAM) policies were not Installed.
  • D. The user lacks the permission to deploy within Cloud Manager.

Answer: D


NEW QUESTION # 25
Your customer calls you because one application is not able to access a NetApp ONTAP S3 bucket. While
reviewing the EMS log on the cluster, you see the following message:

The same credentials work in another application.
In this scenario, what would cause this problem?

  • A. The application is using v2 signatures.
  • B. The application is trying to log in as an anonymous user.
  • C. The application is using v4 signatures.
  • D. The application is trying to access using the HTTP protocol.

Answer: B


NEW QUESTION # 26
Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS(DDNS)
capability available in NetApp ONTAP to easily advertise both data UFs to their clients. Currently. DNS is
only responding with one data LIF. DDNS is enabled on the domain controllers.

Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose
two.)

  • A. Remove the NFS protocol from the cifs_01 data LIF.
  • B. Disable the -vserver-fqdn parameter for the SVM DDNS services.
  • C. Enable the -use-secure parameter for the SVM DDNS services.
  • D. Enable the -is-enabledparameter for the SVM DDNS services

Answer: B,D


NEW QUESTION # 27
You are deploying NetApp ONTAP Select. When trying to add VMware vCenter to the inventory, you receive
the message shown below.
Credential authentication failed for x.x.x.x with: HostConnectionFailed
In this scenario, how would you correct this problem?

  • A. Change the IP address of the vCenter server.
  • B. Change the IP address of the ONTAP Select Deploy VM.
  • C. Change the gateway address of the ONTAP Select Deploy VM.
  • D. Change the vCenter password.

Answer: D


NEW QUESTION # 28
You have a 4-node NetApp ONTAP 9.8 cluster with an AFF A400 HA pair and a FAS8300 HA pair with 16
TB NL-SAS drives. You are asked to automatically tier 150 TB of Snapshot copy data from the AFF A400
aggregates to the FAS8300.
In this scenario, which ONTAP license must be added to the cluster to accomplish this task?

  • A. S3 license
  • B. FabricPool license
  • C. VE license
  • D. TPM license

Answer: D


NEW QUESTION # 29
A customer is calling you to troubleshoot why users are unable to connect to their CIFS SVM.

Referring to the Information shown in the exhibit, what Is the source of the problem?

  • A. The aggregate aggr2 has a failed disk.
  • B. The databases On Node03 must be Switched from secondary to master.
  • C. Thev1db database is offline.
  • D. The broken disk in Node03 is the source of the problem.

Answer: B


NEW QUESTION # 30
When an administrator tries to create a share for an existing volume named voll, the process fails with an error.

Referring to the exhibit, what Is the reason for the error?

  • A. The CIFS service is not in workgroup mode.
  • B. The volume must have a type of DP.
  • C. The CIFS service is not authenticating properly with the domain controller.
  • D. The volume has not beenmounted.

Answer: D


NEW QUESTION # 31
An administrator receives the following error message:

What are two causes for this error? (Choose two.)

  • A. There is excessive SATA HDD load.
  • B. A disk is falling.
  • C. There Is excessive SSD load causing the wear leveling to become unbalanced.
  • D. An SSD disk is performing garbage collection to create a dense data layout.

Answer: A,C


NEW QUESTION # 32
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is
accessed indirectly. The system node run -node -command netstat command shows retransmits and packet
drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster
interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP
9.8 software.
In this scenario, what is causing this problem?

  • A. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
  • B. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
  • C. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
  • D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.

Answer: C


NEW QUESTION # 33
A storage administrator reports that a monitoring toot is reporting that the storage controller reads between
90% to 93% CPU use. You run the sysstat -m command against thenode in question.

Referring to the exhibit, which statement is correct?

  • A. You should immediately investigate further bygathering perfstat data and opening a support case.
  • B. The customer should be advised to exclude certain workflows to reduce use.
  • C. The CPU Is not a first-order monitoring metric for ONTAP.
  • D. High network exempt use could be a problem.

Answer: A


NEW QUESTION # 34
A user mentions that their home drive, that Is an export within a volume, is no longer allowing them to save
files. The drive reports that it Is full, even though It shows that minimal data is written to it.
Which statement would explain this behavior?

  • A. The mount is stale and uses a cached version of the volume.
  • B. Other files within the volume are also owned by the user, exceeding the user quota.
  • C. The client system needs to remount the export to show the proper space.
  • D. Other users wrote to this user's home drive.

Answer: B


NEW QUESTION # 35
Which two automation methods does NetApp ONTAP Select support? (Choose two.)

  • A. REST
  • B. Anslble
  • C. PHP
  • D. Docker

Answer: A,B


NEW QUESTION # 36
A customer with an FC MetroClusterconfiguration that is running NetApp ONTAP 9.8 software experienced a
site outage and wants to know why the MetroClusler configuration did not switch over to the other site.
What are two reasons for this problem? (Choose two.)

  • A. The ISLs were down between the sites.
  • B. An ISL link was not operating at 16Gbps.
  • C. There was a failed PSU inthe switchover site.
  • D. The site had unmirrored aggregates.

Answer: C,D


NEW QUESTION # 37
After users start reporting the Inability to create new flies in a CIFS share, you find EMS events for
wafl.dir.size.max logged for the volume of the SVM to which the share points.
In this scenario, which action should you take to solve this issue?

  • A. Increase the maximum directory size for the volume.
  • B. Increase the maximum numberof files for the volume.
  • C. Move the volume to a different aggregate.
  • D. Delete unneeded files from the directory.

Answer: B


NEW QUESTION # 38
You ate connecting a Windows Server 2019 hostto ISCSI LUNs on a 4-node AFF A250 cluster running
NetApp ONIAP 9.8 software. The host is unable to connect to the target interface, and the ONTAP event log
has the message shown below.
ISCSI: network interface identifier disabled for use; incoming connection discarded
In this scenario, what is the cause of this connection issue?

  • A. CHAP isnot configured correctly for the specified initiator.
  • B. The WWPN was not added to the initiator group.
  • C. iSNS is not enabled on the storage virtual machine.
  • D. The iSCSI service is not enabled on the interface.

Answer: B


NEW QUESTION # 39
......

Exam Materials for You to Prepare & Pass NS0-593 Exam: https://exam-labs.itpassleader.com/NetworkAppliance/NS0-593-dumps-pass-exam.html

0
0
0
0